Skip to main content
[image_with_animation image_url=”418″ alignment=”” animation=”Fade In” border_radius=”none” box_shadow=”none” max_width=”100%”][split_line_heading]

Base units

[/split_line_heading]
[image_with_animation image_url=”375″ alignment=”center” animation=”None” border_radius=”none” box_shadow=”none” max_width=”100%”]
[tabbed_section style=”vertical_modern” tab_color=”Accent-Color”][tab icon_family=”none” title=”airpointer 2D” id=”1556786375485-4″ tab_id=”1556786375486-4″]

airpointer 2D

2 of Pollutants Standard modules

Dimensions (H/W/D, w/o handle and sample inlets) 890/782/400 mm35/30.8/15.8 in.
Weight 65.8 kg/145.1 lbs
Power consumption* max. 670 W
Flow <2000ccm/min +2000 ccm/min for nephelometer
  • Construction:
    Well-isolated double aluminium constructionStandard monitoring modules on removable drawers
    Rugged, inconspicuous burglar-proof design
  • Standard equipment:
    Internal air conditioning and temperature control
    Maintenance door
    Cylinder lock (standard)
    Zero air supply
  • Operating temperature
    -20 °C/-4°F to +42 °C/108°F (optional heating for down to -40 °C/-40°F)
  • Options
    Various types of mounting bracketsWireless communication (GPRS, 3G,…)
    Sample gas conditioning (high relative humidity, high PM exposure)
    Integration of external devices and instruments (e.g. 4-20 mA, RS-232, Modbus via IP,…)
    Solutions to communicate with external data systems (e.g. TCP-IP, Modbus via IP, RS-232, 4-20 mA,…)
    Various base frames and handling devices for on-site operation (roadside, workshop, indoor, pickup truck, trailer,…)
[/tab][tab icon_family=”none” title=”airpointer 4D” id=”1556786375585-4″ tab_id=”1556786375586-9″]

airpointer 4D

4 of Pollutants Standard modules

Dimensions (H/W/D, w/o handle and sample inlets) 1120/782/400 mm
44.1/30.8/15.8 in
Weight 73.9 kg/162.9 lbs
Power consumption* max. 670 W
Flow <3000ccm/min +2000ccm/min for nephelometer
  • Construction:
    Well-isolated double aluminium constructionStandard monitoring modules on removable drawers
    Rugged, inconspicuous burglar-proof design
  • Standard equipment:
    Internal air conditioning and temperature control
    Maintenance door
    Cylinder lock (standard)
    Zero air supply
  • Operating temperature
    -20 °C/-4°F to +42 °C/108°F (optional heating for down to -40 °C/-40°F)
  • Options
    Various types of mounting bracketsWireless communication (GPRS, 3G,…)
    Sample gas conditioning (high relative humidity, high PM exposure)
    Integration of external devices and instruments (e.g. 4-20 mA, RS-232, Modbus via IP,…)
    Solutions to communicate with external data systems (e.g. TCP-IP, Modbus via IP, RS-232, 4-20 mA,…)
    Various base frames and handling devices for on-site operation (roadside, workshop, indoor, pickup truck, trailer,…)
[/tab][tab icon_family=”none” title=”airpointer 4D HC” id=”1556786375655-7″ tab_id=”1556786375656-0″]

airpointer 4D HC

4 of Pollutants Standard modules
Type approved PM10 or PM2.5 monitor (Thermo 5030 SHARP, Met One BAM1020)

Dimensions (H/W/D, w/o handle and sample inlets) 1200/782/615 mm
47.2/30.8/24.2 in.
Weight 110 kg/242.5 lbs
Power consumption* max. 1100 W
Flow  <2000ccm/min +16.7l/min for PM monitor
  • Construction:
    Well-isolated double aluminium constructionStandard monitoring modules on removable drawers
    Rugged, inconspicuous burglar-proof design
  • Standard equipment:
    Internal air conditioning and temperature control
    Maintenance door
    Cylinder lock (standard)
    Zero air supply
  • Operating temperature
    -20 °C/-4°F to +42 °C/108°F (optional heating for down to -40 °C/-40°F)
  • Options
    Various types of mounting bracketsWireless communication (GPRS, 3G,…)
    Sample gas conditioning (high relative humidity, high PM exposure)
    Integration of external devices and instruments (e.g. 4-20 mA, RS-232, Modbus via IP,…)
    Solutions to communicate with external data systems (e.g. TCP-IP, Modbus via IP, RS-232, 4-20 mA,…)
    Various base frames and handling devices for on-site operation (roadside, workshop, indoor, pickup truck, trailer,…)
[/tab][/tabbed_section]

Pollutants Standard modules

Pollutant Weight
NO/NO2/NOX Weight: 12.0 kg/26.5 lbs optional: span module
NH3 Only combined with NOX module
O3 Weight: 5.8 kg/12.8 lbs,optional: span module
SO2 (H2S) Weight: 8.5 kg/18.7 lbs,optional: span module; optional: H2S module
CO Weight: 9.0 kg/19.8 lbs,optional: span module

More sensor modules

  • Photoionisation detector (PID) for volatile organic compounds (VOC)
  • Nephelometer for indicative PM monitoring (PM10, PM2.5)
  • Meteorological sensors: wind direction, wind velocity, temperature, air pressure, relative humidity, precipitation, made by various manufacturers
  • Traffic data sensors: traffic count, made by various manufacturers
  • Noise sensors, made by various manufacturers
  • Electrochemical sensors for formaldehyde, ethane, chlorine…
  • For industrial applications, environmental hygiene, and indoor air quality monitoring (IAQ)
  • Sensors for monitoring indoor CO2 (IAQ)
  • Navigation system (GPS) for linking monitoring data with geographical data